Logo of TSK Prüfsysteme GmbH
Abstand
Abstand
Abstand
Abstand
Abstand
weißer PfeilThe way to make it | different

Module Tester FT5010

Product Structure FT5010
FT5010 19" Module

The module test system FT5010 comprises four main components (standard PC, measurement system, test matrix and the adaptation) as well as the Test Software CS WIN nx with various features and options.
The measurement system is modular and extendable for all desired test tasks. The test matrix is also modular and thus, adjustable.
A special advantage lies in operating several test matrixes with different specifications. Thus, the possibility exists of stimulating the devices under test with respective voltages, and at the same time taking measurements of the same.

Equipment

  • 19" housing
  • Measurement technique
  • Voltage and current generators
  • Interface to external measurement devices
  • 8 potential-free inputs and outputs (24 volt via an external power pack)  
  • 9 slots for test point cards
  • Four main components (standard PC, measurement system, test matrix and adaptation) 

Areas of Application

  • End of Line - Test
  • Quality and Function Tests in the automotive supplier industry
  • Tests in conjunction with development and first sample testing
    Features
  • Simultaneous stimulation and measurement of units under test
  • Modular measurement technology
  • Modular, adjustable test matrix
  • Several test matrixes with different specifications can be operated

Technical Specifications: FT5010 Measurement Unit

Voltage metering / Current Measurement
Range 
resolution better than
Accuracy better than
Automatic
Measuring range change-over



0 ... 800mV, ... 80V, decadal
0.1% from range
0.1% ± 0.1% from range

Resistance Measurement
Bi-pole measurement
Four-terminal  measurement 
Resolution 
Accuracy (without TP-cards)

Four-terminal  measurement 
Upper voltage
Automatic measuring range change-over, arbitrary


0 ... 10 Ohm, ... 100 MOhm, decadal
0 ... 0.1Ohm, ... 100 Ohm, decadal
0.2%
1% (1Ohm ... 1MOhm)
2 % (1 ... 10MOhm)
5 % (> 10MOhm)
0,5% (0,1 Ohm ... 100 Ohm)
5 ... 60V, Standard (up to 10MOhm), 5V

Capacity Measurement
Range
Resolution
Accuracy
discharge of devices under test before beginning measurement


100pF...10mF, decadal
0.1% from Range
3% ± 10pF

Diodes, Z-Diodes
Forward- /Block Voltage
Test current
Accuracy
Upper voltage

 
0,2V ... 55V
1 ... 100mA
0.1V
5 ... 60V

Programmable voltage / power source  [LVDC-Gen2]
Output
Output voltage
Output power max.
Voltage adjustment
Resolution
Accuracy 
Power adjustment
Range
Resolution
Accuracy




0V ... 60V
max. 2A continuous rate

0.05V
0.2% ± 0.1V

0.15 ... 2A
0.01A
0.1A

Measurement of output voltage and power via LV measurement technology (VMU).
Constant voltage control or constant control depending on load.

 Data Sheet (PDF)